Product Name: Hotsale Intelligent Process Dry Air Cooler System
Air Volume: 63200 Cubic Meter
Feature: Circulating Water Pump
Net Weight: 1312kg
Fan Spec: 4*630
Fan Motor AMP: 20.0 a
Fan Motor Power: 11200W
Inlet Od: Dn125
Outlet Od: Dn125
Trademark: Shenglin
Transport Package: Wooden Packing
Specification: ISO9001: 2000
Origin: Shanghai, China
HS Code: 8415909000
Model NO.: SHSL-D2-604-14X630F2
Certification: RoHS, ISO
Condition: New
Product Name: Hotsale Intelligent Process Dry Air Cooler System
Air Volume: 63200 Cubic Meter
Feature: Circulating Water Pump
Net Weight: 1312kg
Fan Spec: 4*630
Fan Motor AMP: 20.0 a
Fan Motor Power: 11200W
Inlet Od: Dn125
Outlet Od: Dn125
Trademark: Shenglin
Transport Package: Wooden Packing
Specification: ISO9001: 2000
Origin: Shanghai, China
HS Code: 8415909000
      Hotsale Intelligent Process dry air cooler system
Description of Technology: The closed-loop, dry cooling technology operates by pumping water returning from the process into heat exchangers and cooling it with ambient air flow. This process provides clean water at the right temperature to process machines year round. Desired water temperatures are continuously met through control and software that provides fully-automatic water and energy savings adjustments based on actual thermal load and outdoor temperatures. To maintain water below setpoint in hot weather, defined as 29.4°C (85°F), outside air passes through an adiabatic chamber before reaching the air-to-water heat exchanger coils. Adiabatic mode keeps LWT below 35°C (95°F) even when ambient temperatures reach 48.9°F (120°F). In the chamber, a fine mist of water (from a separate source) is pulsed into the air stream, evaporates immediately and cools the air before it impinges on the cooling coils. The spray function and volume of water used is controlled by the microprocessor based on ambient temperatures. Only cool, dry air makes contact with the heat exchanger coils, creating the concept of "dry cooling". This ensures coils are kept completely dry and free of scale.
Technical data
Models
SBF634F10
SBF634H10
SBF636F10
SBF636H10
SC4 cooling cap(KW)
48.6
57.2
65.2
79.2
SC5 cooling cap(KW)
41.6
50.2
53.6
64.2
Surface    Â
210
292
312
436
Air flow    m³/h
63200
59000
94800
88500
Air throw   m
35
32
40
38
Net weight   kg
660
740
960
1080
Fan spec.
4*630
4*630
6*630
6*630
Fan mot.ampere  A
20.0
20.0
30.0
30.0
Fan mot. Power  W
11200
11200
16800
16800
Electric defrost   A
56.6
56.6
85.5
85.5
Electric defrost   W
32250
32250
48750
48750
W-defrost flow rate  m³/h
14.0
17.3
17.3
21.6
Inlet OD      inch
1-3/8*2
1-3/8*2
1-3/8*2
1-3/8*2
Outlet OD     inch
2-1/8*2
2-1/8*2
2-1/8*2
2-1/8*2
*The above performance data are for the models with imported brand fan motors. *Two-system design for standard blast freezer models. As a result of continuing research and design efforts by Shenglin, aimed at offering top quality and innovative products. Â
      Hotsale Intelligent Process dry air cooler system
Description of Technology: The closed-loop, dry cooling technology operates by pumping water returning from the process into heat exchangers and cooling it with ambient air flow. This process provides clean water at the right temperature to process machines year round. Desired water temperatures are continuously met through control and software that provides fully-automatic water and energy savings adjustments based on actual thermal load and outdoor temperatures. To maintain water below setpoint in hot weather, defined as 29.4°C (85°F), outside air passes through an adiabatic chamber before reaching the air-to-water heat exchanger coils. Adiabatic mode keeps LWT below 35°C (95°F) even when ambient temperatures reach 48.9°F (120°F). In the chamber, a fine mist of water (from a separate source) is pulsed into the air stream, evaporates immediately and cools the air before it impinges on the cooling coils. The spray function and volume of water used is controlled by the microprocessor based on ambient temperatures. Only cool, dry air makes contact with the heat exchanger coils, creating the concept of "dry cooling". This ensures coils are kept completely dry and free of scale.
Technical data
Models
SBF634F10
SBF634H10
SBF636F10
SBF636H10
SC4 cooling cap(KW)
48.6
57.2
65.2
79.2
SC5 cooling cap(KW)
41.6
50.2
53.6
64.2
Surface    Â
210
292
312
436
Air flow    m³/h
63200
59000
94800
88500
Air throw   m
35
32
40
38
Net weight   kg
660
740
960
1080
Fan spec.
4*630
4*630
6*630
6*630
Fan mot.ampere  A
20.0
20.0
30.0
30.0
Fan mot. Power  W
11200
11200
16800
16800
Electric defrost   A
56.6
56.6
85.5
85.5
Electric defrost   W
32250
32250
48750
48750
W-defrost flow rate  m³/h
14.0
17.3
17.3
21.6
Inlet OD      inch
1-3/8*2
1-3/8*2
1-3/8*2
1-3/8*2
Outlet OD     inch
2-1/8*2
2-1/8*2
2-1/8*2
2-1/8*2
*The above performance data are for the models with imported brand fan motors. *Two-system design for standard blast freezer models. As a result of continuing research and design efforts by Shenglin, aimed at offering top quality and innovative products. Â
The natural breeze generated by the farm Hvls fan blows on the human body, promoting the evaporation of sweat and taking away heat, cooling the body and bringing a cooling sensation. Usually, this cooling sensation can reach 5-8 ℃. The three-dimensional natural wind blown by Industrial Fans is more comfortable. On the one hand, three-dimensional blowing of the human body in all directions allows for a large evaporation area. On the other hand, humans have accumulated a warm experience of natural wind in nature. Once there is a change in wind speed, the human body naturally feels extremely comfortable and cool.