How to maintain a precision pressure gauge
Precision pressure gauge - How to maintain the pressure gauge Seeing this title, someone's head began to get a headache again. Because, the maintenance of the pressure gauge is necessary, and it is more frequent in winter. Maintenance of other pressure gauges: 1) The pressure gauge should be kept clean and the glass on the dial should be bright and clear, so that the pressure value indicated by the pointer in the dial can be clearly seen. The pressure gauge with broken glass or unclear dial shall be discontinued.
EVA Faux Teak Sheet comes in double layers EVA material, it appears grooves to show the bottom color after the roller cutting, which makes it looks like a teak wood. So instead of using a real wood for the boat flooring, more and more people put their focus on this no maintain and Eco-friendly EVA marine sheet.
Made from marine grade UV resistant, closed cell, high density EVA foam material, it stands perfectly even in a strong sunlight area. And the EVA foam material makes it softer and more comfortable for people standing there bare feet than real teak or PVC teak. Some would concerned if the boat mat would be not durable to use since it is made from foam material. Well, it may not hard like real teak or PVC teak, and compete the durability with those two, but with a higher density EVA foam, we are able to compete with other suppliers who try to compromise the density to reach to a lower price.
The sheet comes in 230cm x 90cm or 250cm x 120cm, user can cut the sheets into size to fit the shape of boat decking, then just peel and stick since the sheets we offer is with 3M adhesive on the backing. It can be applied on boat decking of course, and other like swim platform pad, helm station pad or simple seat pad.
What's more, this kind of sheets can be applied in recreation vehicle for luxury flooring, a safe traction mat for the edge of swimming pool, a beautiful looking for flooring in room or balcony.
Eva Faux Teak Sheet,Faux Teak Sheet,Foam Faux Teak Sheet,Faux Teak Strip,Faux Teak Edging,Eva Faux Teak Deck Sheet Huizhou City Melors Plastic Products Co., Limited , https://www.melorsfloor.com
Here we will discuss what kind of state differential pressure gauges can be used to maintain, maintain and repair the pressure gauges.
1. Before the installation of the pressure gauge, the models and specifications must be carefully checked. The pointer must not be deflected out of the black mark. Otherwise, it should be recalibrated or replaced.
2, pressure gauge should be installed in the surrounding environment (or medium) temperature -40 ~ +55 °C, relative humidity is not more than 85%, vibration or pressure pulsation of the measured pressure does not affect the correct reading and other environments.
3, the pressure gauge should not be reversed high and low pressure, pressure should be given to the high pressure, after the low pressure, unilateral pressure, does not allow more than the maximum pressure.
4. The pressure gauge shall be installed vertically and strive to maintain the same horizontal position with the pressure-taking point. Otherwise, the additional error caused by the difference in level shall be introduced accordingly.
2) The connecting tube of the pressure gauge should be purged regularly to avoid clogging. For pressure gauge connecting pipes containing more oil or other viscous material gases, especially for purging.
3) The pressure gauge often pays attention to check whether the rotation and fluctuation of the pressure gauge pointer is normal, and check whether the plug on the connecting tube is in the open state.
4) The pressure gauge must be calibrated regularly. Pressure gauges that have exceeded the verification period should be discontinued. In the normal operation of boilers and pressure vessels, if abnormal pressure gauge indications or other suspicious signs are found, they should be immediately checked and corrected.
Stainless steel electric contact pressure gauge maintenance:
1. The maximum current through the pressure gauge's electrical contact must not exceed 3A (amperes), otherwise it is self-negative.
2. The pressure gauge should be installed vertically. Avoid collisions and vibration during handling.
3, the pressure gauge should be in the ambient temperature of -40 °C - +70 °C relative humidity is not greater than 85%, and the vibration or the measured medium of the sharp pulse on reliable contact and accurate letter reading without affecting the use of the place.
4. The electrical circuit of the pressure gauge (refer to the schematic diagram) is carefully checked after setting and connecting, and the test operation is performed.
5, pressure gauge in the adjustment of a given value, must use slotted screwdriver.
6. When measuring the static load, the pressure gauge can be used up to 3/4 of the upper limit of the measurement, and when measuring the alternating load, it can be used up to 2/3 of the upper limit of the measurement. For the instantaneous measurement, the upper limit can be used.
7. The pressure gauge should be added with isolation device and buffer device when measuring large viscosity medium and drastic fluctuation pressure.
8. Pressure gauges should be checked regularly (at least once every three months)
9. Pressure gauges should always be kept dry and clean during use and properly maintained.