Transport Package: Standard Export Packag with Pure English
Specification: 1100*850*1750mm
Origin: Shanghai, China
HS Code: 9022199090
DW-XRD-Y3000 Model X-ray diffraction instrument
Y3000 Series diffractometer is designed for materials reserarch and industrial products analysis. It is the perfect combination of conventional analysis with special-purpose measurement products. •The perfect combination of hardware and software systems meets the needs of academics and researchers in different application areas.High precision diffraction angle measurement system obtains more accurate resultsHigh stability of the X-ray generator control system gets more stable repeatability precisionProgrammable operation, integrated structure design, easy operation, elegant outlook.X-ray diffraction (XRD) is a versatile test instrument to reveal the crystal structure and chemical information:Unkown samples in a variety of phase identificationMixed samples with known quantitative phase analysisCrystal structure analysisCrystal structure changes under Unconventional conditions (high temperature, low temperature conditions)•Analysis on material surface film •Analysis on metal material texture and stress Technique parameter
XRD-Y3000
Rated power
3kW
 Tube voltage
 10-60kV
 Tube current
 5-80mA
X-ray tuble
glass tube, ceramic tube, ripple ceramic tube: Cu, Fe, Co, Cr, Mo etc, Power 2kW
 Focus size
 1 x 10mm or 0.4 x 14mm or 2 x 12mm
Stability
≤0.01%
Goniometer structure
Horizontal ( θ-2 θ)
 Radius of diffraction
 185mm
Scanning range
0-164
Scanning speed
0.0012° - 70° min
Max. revolving speed
100° /min
Scanning fashion
θ-2θ linkage, θ,2θ single action; continuous or stepping scanning
Angle repeatable accuracy
1/1000°
Minimal stepping angle
1/1000°
 Detector
 proportional counters(PC) or scintillation counters(SC)
Maximal counting rate of linearity
5 x 105CPS ( with the compensate function of drop out counting )
Energy resolution ratio
≤25% (PC),≤50% (SC)
Counting fashion
differential coefficient or integral, PHA automatically, Dead time regulate
Stability of system measure
≤0.01%
Scattered rays dose
≤1 μ Sv/h ( without X-ray protective device )
Instrument integrative stability
≤0.5%
Figure size
1100 x 850 x 1750mm
DW-XRD-Y3000 Model X-ray diffraction instrument
Y3000 Series diffractometer is designed for materials reserarch and industrial products analysis. It is the perfect combination of conventional analysis with special-purpose measurement products. •The perfect combination of hardware and software systems meets the needs of academics and researchers in different application areas.High precision diffraction angle measurement system obtains more accurate resultsHigh stability of the X-ray generator control system gets more stable repeatability precisionProgrammable operation, integrated structure design, easy operation, elegant outlook.X-ray diffraction (XRD) is a versatile test instrument to reveal the crystal structure and chemical information:Unkown samples in a variety of phase identificationMixed samples with known quantitative phase analysisCrystal structure analysisCrystal structure changes under Unconventional conditions (high temperature, low temperature conditions)•Analysis on material surface film •Analysis on metal material texture and stress Technique parameter
XRD-Y3000
Rated power
3kW
 Tube voltage
 10-60kV
 Tube current
 5-80mA
X-ray tuble
glass tube, ceramic tube, ripple ceramic tube: Cu, Fe, Co, Cr, Mo etc, Power 2kW
 Focus size
 1 x 10mm or 0.4 x 14mm or 2 x 12mm
Stability
≤0.01%
Goniometer structure
Horizontal ( θ-2 θ)
 Radius of diffraction
 185mm
Scanning range
0-164
Scanning speed
0.0012° - 70° min
Max. revolving speed
100° /min
Scanning fashion
θ-2θ linkage, θ,2θ single action; continuous or stepping scanning
Angle repeatable accuracy
1/1000°
Minimal stepping angle
1/1000°
 Detector
 proportional counters(PC) or scintillation counters(SC)
Maximal counting rate of linearity
5 x 105CPS ( with the compensate function of drop out counting )
Energy resolution ratio
≤25% (PC),≤50% (SC)
Counting fashion
differential coefficient or integral, PHA automatically, Dead time regulate